Human cardiac troponin T(cTn-T)ELISA Kit

Code CSB-E13047h
Size 96T,5×96T,10×96T
Price Request a Quote or Start an on-line Chat
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* The sample kit cost can be deducted from your subsequent orders of 96T full size kits of the same analyte at 1/5 per kit, until depleted in 6 months. Apply now

Product Details

Target Name
troponin T type 1 (skeletal, slow)
Alternative Names
ANM ELISA Kit; MGC104241 ELISA Kit; NEM5 ELISA Kit; Skeletal ELISA Kit; Slow ELISA Kit; slow skeletal muscle ELISA Kit; Slow skeletal muscle troponin T ELISA Kit; sTnT ELISA Kit; Tnnt1 ELISA Kit; TNNT1_HUMAN ELISA Kit; TNT ELISA Kit; TnTs ELISA Kit; Troponin T ELISA Kit; Troponin T slow skeletal muscle ELISA Kit; Troponin T type 1 (skeletal slow) ELISA Kit; troponin T1 skeletal slow ELISA Kit; Troponin T1, slow skeletal type ELISA Kit
Abbreviation
TNNT1
Uniprot No.
Species
Homo sapiens (Human)
Sample Types
serum, plasma
Detection Range
0.156 ng/mL-10 ng/mL
Sensitivity
0.039 ng/mL
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Signal Transduction
Assay Principle
quantitative
Measurement
Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human cTn-T in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
 SampleSerum(n=4)
1:1Average %94
Range %90-100
1:2Average %90
Range %85-99
1:4Average %98
Range %90-107
1:8Average %92
Range %85-100
Recovery
The recovery of human cTn-T spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample TypeAverage % RecoveryRange
Serum (n=5) 9892-104
EDTA plasma (n=4)9590-100
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/mlOD1OD2AverageCorrected
102.288 2.391 2.340 2.194
51.447 1.508 1.478 1.332
2.50.824 0.838 0.831 0.685
1.250.525 0.547 0.536 0.390
0.6250.316 0.329 0.323 0.177
0.3120.264 0.273 0.269 0.123
0.1560.225 0.234 0.230 0.084
00.145 0.146 0.146  
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx
Description

This Human TNNT1 ELISA Kit was designed for the quantitative measurement of Human TNNT1 protein in serum, plasma. It is a Sandwich ELISA kit, its detection range is 0.156 ng/mL-10 ng/mL and the sensitivity is 0.039 ng/mL .

Citations

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

Target Background

Function
(From Uniprot)
Troponin T is the tropomyosin-binding subunit of troponin, the thin filament regulatory complex which confers calcium-sensitivity to striated muscle actomyosin ATPase activity.
Gene References into Functions
  1. High TNNT1 expression is associated with breast cancer. PMID: 30031058
  2. This study describes the first TNNT1 mutation that transmits in an autosomal dominant fashion to cause nemaline myopathy. PMID: 29178646
  3. investigated the effects of one of these mutations, K247R of TnT, on the picosecond dynamics of the Tn core domain (Tn-CD), consisting of TnC, TnI and TnT2 (183-288 residues of TnT), by carrying out the quasielastic neutron scattering measurements on the reconstituted Tn-CD containing either the wild-type TnT2 (wtTn-CD) or the mutant TnT2 (K247R-Tn-CD) in the absence and presence of Ca(2+) PMID: 28923663
  4. Data suggest that mutations in troponin C (TnC, A8V) and troponin T (TnT, delta14-TnT) found in patients with hypertrophic cardiomyopathy together fully stabilize the active M state of regulated actin (the actin-tropomyosin-troponin complex). PMID: 28530094
  5. pathogenesis of TNNT1 myopathies PMID: 27429059
  6. Copeptin and troponin T measurement could potentially improve the prehospital diagnostic and prognostic classification of patients with a suspected AMI. PMID: 27903076
  7. TNNT1 genetic and epigenetic variations are associated with HDL-C levels and coronary artery disease. PMID: 26950807
  8. Three homologous genes have evolved in vertebrates to encode three muscle type-specific TnT isoforms: TNNT1 for slow skeletal muscle TnT, TNNT2 for cardiac muscle TnT, and TNNT3 for fast skeletal muscle TnT. PMID: 26774798
  9. Nemaline body myopathy Palestinian patients were found to have a novel mutation in troponin T1. PMID: 26296490
  10. troponin T and creatinine kinase isoenzyme (CK-MB) have roles in combined renal and myocardial injuries in asphyxiated infants PMID: 24625749
  11. Biopsy-proven acute and viral myocarditis is associated with elevated concentrations of hs-TnT. PMID: 24781421
  12. Troponin T1 blood levels had a positive association with increased risk for hypertrophic cardiomyopathy. PMID: 24020864
  13. TNNT1 DNA methylation levels were positively correlated with mean HDL particle size, HDL-phospholipid, HDL-apolipoprotein AI, HDL-C and TNNT1 expression levels. PMID: 23244308
  14. Human slow skeletal troponin T (HSSTnT) isoforms, despite being homologues of cardiac TnT may display distinct functional properties in muscle regulation. PMID: 22977240
  15. analysis of parameters of oxygen-dependent metabolism of neutrophils by NBT test and levels of vWF antigen in the serum can be used for predicting the risk of unfavorable outcome in patients with ACS and normal troponin T PMID: 22448368
  16. In heart failure patients with normal ejection fraction, highly sensitive troponin T and heart fatty acid binding protein are elevated independent of coronary artery disease. PMID: 21729325
  17. baseline cTnT levels are higher in patients with MPI evidence of reversible myocardial ischaemia than those without reversible ischaemia PMID: 22239123
  18. carotid-femoral pulse wave and office pulse pressure are associated with minimally elevated hsTnT levels in the elderly PMID: 21784424
  19. the hypertrophic phenotype associated with the TnT mutations can be characterized by a significant increase in disorder of rigor cross-bridges. PMID: 21683708
  20. Elevated serum troponin T levels are associated with different conditions related to the severity of hypertrophic cardiomyopathy. PMID: 21111984
  21. Cardiac troponin T and creatine kinase have roles in infarct size and left ventricular function after acute myocardial infarction PMID: 21448949
  22. The occurrence of myocardial infarction is associated with elevated troponin T levels. PMID: 19916752
  23. Among athletees, faster runners demonstrate significantly stronger cardoac TnT releases and inflammation signs. PMID: 20380359
  24. troponin-T mutations were responsible for 3% of the hypertrophic cardiomyopathy cases in our study population PMID: 20038417
  25. Troponin T may have a role in pulmonary embolism progeresion to death PMID: 19541721
  26. TNT is a biochemical marker of susceptibility to hypoxia in infants of type 1 diabetic mothers. PMID: 19690080
  27. Data suggest that inefficient incorporation into myofilament is responsible for the instability of mutant slow troponin T in Amish nemaline myopathy. PMID: 15665378
  28. Report adaptation by alternative RNA splicing of slow troponin T isoforms in type 1 but not type 2 Charcot-Marie-Tooth disease. PMID: 18579801
  29. slow TnT was encoded by two different transcripts in significantly different ratios in myotonic dystrophy type 1 and myotonic dystrophy type 2 muscles. PMID: 19326042

Show More

Hide All

Involvement in disease
Nemaline myopathy 5 (NEM5)
Protein Families
Troponin T family
Database Links

HGNC: 11948

OMIM: 191041

KEGG: hsa:7138

STRING: 9606.ENSP00000467176

UniGene: Hs.631558

icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2024 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1