Rat hydroxyproline,Hyp ELISA Kit

Code CSB-E08838r
Size 96T,5×96T,10×96T
Price Request a Quote
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* Sample kit cost can be deducted as a $30 credit for each 96-assay kit of the same analyte and brand you subsequently purchase within six months until depleted. More details >>
Interested in a trial size? Please leave a message below.
Have Questions? Leave a Message or Start an on-line Chat

Product Details

Target Name
hydroxyproline,Hyp
Abbreviation
Hyp
Species
Rattus norvegicus (Rat)
Sample Types
serum, plasma, tissue homogenates
Detection Range
0.156 ng/mL-10 ng/mL
Sensitivity
0.078 ng/mL
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Signal Transduction
Assay Principle
quantitative
Measurement
Competitive
Precision
Intra-assay Precision (Precision within an assay): CV%<8%      
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%<10%      
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of rat Hyp in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:200 Average % 87  
Range % 83-90  
1:400 Average % 94  
Range % 90-98  
1:800 Average % 101  
Range % 97-104  
1:1600 Average % 96  
Range % 93-99  
Recovery
The recovery of rat Hyp spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 94 89-98  
EDTA plasma (n=4) 100 95-105  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/ml OD1 OD2 Average    
10 0.112 0.115 0.114    
5 0.186 0.179 0.183    
2.5 0.260 0.269 0.265    
1.25 0.471 0.439 0.455    
0.625 0.615 0.629 0.622    
0.312 1.117 1.139 1.128    
0.156 2.173 2.229 2.201    
0 2.854 2.897 2.876    
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Shelf Life
6 months
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Description

The Rat Hydroxyproline (Hyp) ELISA kit is a valuable tool for researchers working with rat samples, offering a quantitative assay for hydroxyproline. This ELISA kit is specifically designed for rat species and can analyze serum, plasma, and tissue homogenates. With a detection range of 0.156 ng/mL to 10 ng/mL and a sensitivity of 0.078 ng/mL, it provides precise measurements within a short assay time of 1-5 hours, requiring a sample volume of 50-100 µl. The assay principle is competitive, and measurements are taken at a detection wavelength of 450 nm. This kit has been utilized in various studies, including those focusing on liver and lung fibrosis, showcasing its versatility and reliability in diverse research areas.

Citations

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

 Q&A
Q:

Please let us know if it can be used with bone extract sample.

A:
Thanks for your inquiry.
Usually we suggest you test the sample types mentioned in the kit manual. You can do a pretest first if you want to test bone extract sample.
Q:

We are interested in sourcing Human, mouse, rat hydroxyproline,Hyp ELISA Kit from CusaBio. What would be our purchasing price for it?
Also, can you kindly clarify why they are a species specific elisa kit while hydroxyproline is a small molecule?

A:
Thanks for your inquiry.
I will ask our distributor in your area to give you a quote by email.
Hydroxyproline is small molecule and it is the same in different species. There are 3 reasons why we have species specific elisa kits.
1. For different species, the sample matrix is different and the characteristics of antibody used in the kits are also different.
2. The methods of these 3 kits are different. Human kit and mouse kit are based on double antibody sandwich method.
When the kit was developed, it was designed to mimic the presence of hydroxyproline in vivo. It can detect polymerized form. (including the polymerized form with other proteins and self-polymerization form). For human kit, capture antibody is mouse monoclonal antibody and detection antibody is goat polyclonal antibody; For mouse kit, capture antibody is rat monoclonal antibody and detection antibody is goat polyclonal antibody.
Rat kit is based on competitive method. The plate is coated with mouse monoclonal antibody. HRP conjugated HYP competes with the HYP in the sample. The kit can detect the endogenous total HYP, including free form and polymerized form.
3. The reason why different kits use different methods is based on a variety of factors. You can choose the appropriate kit to avoid matrix problems.
Pls let me know if you have any further questions. Thank you.
CUSABIO guaranteed quality
icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2025 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1