| Code | CSB-EL009370HU |
| Size | 96T,5×96T,10×96T |
| Price | Request a Quote |
| Trial Size |
24T ELISA Kit Trial Size (Only USD$150/ kit) * Sample kit cost can be deducted as a $30 credit for each 96-assay kit of the same analyte and brand you subsequently purchase within six months until depleted. More details >> Interested in a trial size? Please leave a message below.
|
| Have Questions? | Leave a Message or Start an on-line Chat |
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
To assess the linearity of the assay, samples were spiked with high concentrations of human GFER in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
| Sample | Serum(n=4) | ||||
1:10 | Average % | 104 | ||||
Range % | 99-109 | |||||
1:20 | Average % | 95 | ||||
Range % | 88-101 | |||||
1:40 | Average % | 89 | ||||
Range % | 84-95 | |||||
1:80 | Average % | 98 | ||||
Range % | 91-104 | |||||
The recovery of human GFER spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 96 | 89-103 | ||||
EDTA plasma (n=4) | 91 | 87-96 | ||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||
| |||||||
pg/ml | OD1 | OD2 | Average | Corrected | |||
100 | 2.344 | 2.434 | 2.389 | 2.251 | |||
50 | 1.708 | 1.667 | 1.687 | 1.549 | |||
25 | 1.269 | 1.228 | 1.249 | 1.111 | |||
12.5 | 0.899 | 0.929 | 0.914 | 0.776 | |||
6.25 | 0.571 | 0.581 | 0.576 | 0.438 | |||
3.12 | 0.384 | 0.363 | 0.373 | 0.236 | |||
1.56 | 0.265 | 0.274 | 0.270 | 0.132 | |||
0 | 0.141 | 0.135 | 0.138 |
| |||
This Human GFER ELISA Kit was designed for the quantitative measurement of Human GFER protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 1.56 pg/ml-100 pg/ml and the sensitivity is 0.39 pg/ml.
Sample type: Serum
Sample species: Human
Sample dilution: 1:20
Review: This human FAD-linked thiol oxidase ALR(GFER) enzyme-linked immunosorbent assay kit really exceeded expectations! The kit is neatly packaged, with complete reagent components and clear labeling. After opening the box, all materials can be quickly identified, saving a lot of verification time. The operation process is designed very reasonably. The steps in the manual are detailed and easy to understand. Even beginners using it for the first time can get started easily. The prompts for key steps such as incubation and washing are particularly practical, effectively avoiding operational errors. During the experiment, the reagent stability was excellent. After sample addition, the reaction was uniform with almost no edge effect. The subsequent color development effect was also very ideal. The linear relationship of the gradient standard was excellent, and the correlation coefficient could stably reach above 0.99. The detection repeatability was also outstanding. The result deviation of multiple detections of the same sample was very small, and the data reliability was completely up to verification. When using it to detect samples, the sensitivity fully meets our experimental requirements. Low-concentration samples can still be accurately detected, and it has strong specificity without the interference problem of non-specific binding. The efficiency of the final result is also very high. By following the procedures in the manual, the test can be completed smoothly within the expected time, saving a large number of experimental cycles. Whether it is from the perspective of operational convenience, reagent stability, or detection accuracy and sensitivity, this kit performs at the top. It provides stable and reliable data support for our ALR(GFER) related research. If there is a need in the future, we will definitely give priority to choosing this one again. I sincerely recommend it to colleagues with related experimental needs!
By Anonymous