Code | CSB-EL001318HU |
Size | 96T,5×96T,10×96T |
Price | Request a Quote |
Trial Size |
24T ELISA Kit Trial Size (Only USD$150/ kit) * Sample kit cost can be deducted as a $30 credit for each 96-assay kit of the same analyte and brand you subsequently purchase within six months until depleted. More details >> Interested in a trial size? Please leave a message below.
|
Have Questions? | Leave a Message or Start an on-line Chat |
Intra-assay Precision (Precision within an assay): CV%<8% | |||||||
Three samples of known concentration were tested twenty times on one plate to assess. | |||||||
Inter-assay Precision (Precision between assays): CV%<10% | |||||||
Three samples of known concentration were tested in twenty assays to assess. | |||||||
To assess the linearity of the assay, samples were spiked with high concentrations of human ADAMTSL2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | |||||||
Sample | Serum(n=4) | ||||||
1:1 | Average % | 99 | |||||
Range % | 94-106 | ||||||
1:2 | Average % | 88 | |||||
Range % | 84-93 | ||||||
1:4 | Average % | 92 | |||||
Range % | 87-98 | ||||||
1:8 | Average % | 102 | |||||
Range % | 98-106 |
The recovery of human ADAMTSL2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | |||||||
Sample Type | Average % Recovery | Range | |||||
Serum (n=5) | 91 | 87-96 | |||||
EDTA plasma (n=4) | 86 | 81-92 | |||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]()
|
This Human ADAMTSL2 ELISA Kit was designed for the quantitative measurement of Human ADAMTSL2 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 3.12 ng/mL-200 ng/mL and the sensitivity is 0.78 ng/mL.
There are currently no reviews for this product.
We are looking into kits to measure ADAMTSL2. We found this product: CSB-EL001318HU - has this kit measured endogenous ADAMTSL2 in plasma or serum and what is the immunogen/calibrator used in this kit? I assume full-length recombinant in some expression system?
The standard of this kit is NS0-derived recombinant protein.
And the kit can detect the ADAMTSL2 protein content in natural samples (serum plasma, etc.), but the status of each sample is different, please check your own actual measurement.
Immunogen: NS0-derived recombinant protein