Code | CSB-EL020987HU |
Size | 96T,5×96T,10×96T |
Price | Request a Quote or Start an on-line Chat |
Trial Size |
24T ELISA Kit Trial Size (Only USD$150/ kit) * The sample kit cost can be deducted from your subsequent orders of 96T full size kits of the same analyte at 1/5 per kit, until depleted in 6 months. Apply now |
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
To assess the linearity of the assay, samples were spiked with high concentrations of human SEMA4A in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
Sample | Serum(n=4) | |||||
1:1 | Average % | 89 | ||||
Range % | 85-93 | |||||
1:2 | Average % | 97 | ||||
Range % | 93-100 | |||||
1:4 | Average % | 91 | ||||
Range % | 88-95 | |||||
1:8 | Average % | 94 | ||||
Range % | 91-99 |
The recovery of human SEMA4A spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 83 | 80-86 | ||||
EDTA plasma (n=4) | 87 | 81-90 | ||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
This Human SEMA4A ELISA Kit was designed for the quantitative measurement of Human SEMA4A protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.312 ng/mL-20 ng/mL and the sensitivity is 0.078 ng/mL.
There are currently no reviews for this product.
1) Can you give me any more information on the standards used in the kit? i.e. if they are full length proteins, are they recombinant, what kind of expression systems have they been made in? Thanks
2) I would also be interested to know what kind of antibodies are used for the capture and detection - i.e. the species of antibody, whether they are polyclonal or monoclonal, which immunogen they were raised against and also whether they are available to purchase separately?
A customer interested in quantifying human semaphorin-4A from serum samples. They are particularly interested in quantifying the extracellular portion of such protein since not all my samples have the cytoplasmic region.