Human Thromboxane B2,TX-B2 ELISA Kit

Code CSB-E08046h
Size 96T,5×96T,10×96T
Price Request a Quote
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* Sample kit cost can be deducted as a $30 credit for each 96-assay kit of the same analyte and brand you subsequently purchase within six months until depleted. More details >>
Interested in a trial size? Please leave a message below.
Have Questions? Leave a Message or Start an on-line Chat

Product Details

Target Name
Thromboxane B2,TX-B2
Abbreviation
TX-B2
Species
Homo sapiens (Human)
Sample Types
serum, plasma, cell culture supernates, tissue homogenates
Detection Range
9.38 pg/mL-600 pg/mL
Sensitivity
2.34 pg/mL
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Signal Transduction
Assay Principle
quantitative
Measurement
Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%<8%      
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%<10%      
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human TX-B2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 96  
Range % 80-105  
1:2 Average % 95  
Range % 85-108  
1:4 Average % 106  
Range % 90-112  
1:8 Average % 95  
Range % 80-110  
Recovery
The recovery of human TX-B2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 96 80-110  
EDTA plasma (n=4) 98 90-108  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
600 3.147 3.121 3.134 2.997  
300 2.534 2.521 2.528 2.390  
150 1.750 1.744 1.747 1.610  
75 1.052 1.046 1.049 0.912  
37.5 0.659 0.644 0.652 0.514  
18.75 0.443 0.428 0.436 0.298  
9.37 0.263 0.284 0.274 0.136  
0 0.134 0.141 0.138    
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Shelf Life
6 months
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx.
Description

Thromboxane B2 (TX-B2) is a stable metabolite of thromboxane A2, a potent bioactive lipid mediator derived from arachidonic acid through the cyclooxygenase pathway. As the primary measurable end product of thromboxane A2 synthesis, TX-B2 serves as a reliable biomarker for thromboxane production and platelet activation. This prostanoid plays important roles in cardiovascular physiology and pathology, making it a valuable target for research examining inflammation, thrombosis, and vascular function.

The Human Thromboxane B2,TX-B2 ELISA Kit (CSB-E08046h) uses a quantitative sandwich measurement principle for detecting TX-B2 in serum, plasma, cell culture supernates, and tissue homogenates. The assay provides a detection range of 9.38 pg/mL to 600 pg/mL with a sensitivity of 2.34 pg/mL. The assay requires 50-100 μL sample volume and can be completed within 1-5 hours. Detection occurs at 450 nm wavelength.

Application Examples

Note: The following application examples are drawn from a selection of publications citing this product. For additional applications, please refer to the full list of references in the "Citations" section.

This ELISA kit has been used in research studies to measure thromboxane B2 levels in human serum samples, serving as a stable biomarker for thromboxane A2 activity in various physiological and pathological conditions. The kit has shown reliable performance in studies examining vasoactive biomarkers and platelet function, where thromboxane B2 serves as an important indicator of cyclooxygenase pathway activity.

Vasoactive biomarker research - Used to quantify thromboxane B2 as a stable metabolite reflecting thromboxane A2 production in cardiovascular and vascular function studies
Platelet function analysis - Applied in measuring thromboxane B2 levels in both serum and platelet supernatant samples to evaluate platelet activation and aggregation pathways
Multi-biomarker profiling - Incorporated into comprehensive biomarker panels alongside other inflammatory and vascular markers to evaluate complex physiological responses
Serum-based studies - Used for routine measurement of circulating thromboxane B2 levels in human subjects as part of broader research examining prostaglandin metabolism

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2025 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1