Mouse Roundabout homolog 4(ROBO4) ELISA kit

Code CSB-EL020057MO
Size 96T,5×96T,10×96T
Price Request a Quote or Start an on-line Chat
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* The sample kit cost can be deducted from your subsequent orders of 96T full size kits of the same analyte at 1/5 per kit, until depleted in 6 months. Apply now

Product Details

Target Name
roundabout homolog 4, magic roundabout (Drosophila)
Alternative Names
Robo4 ELISA Kit; Roundabout homolog 4 ELISA Kit
Abbreviation
ROBO4
Uniprot No.
Species
Mus musculus (Mouse)
Sample Types
serum, plasma, tissue homogenates
Detection Range
0.156 ng/mL-10 ng/mL
Sensitivity
0.039 ng/mL
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Cancer
Assay Principle
quantitative
Measurement
Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of mouse ROBO4 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)
1:1 Average % 86
Range % 81-89
1:2 Average % 98
Range % 94-103
1:4 Average % 86
Range % 83-89
1:8 Average % 98
Range % 95-102
Recovery
The recovery of mouse ROBO4 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range
Serum (n=5) 104 101-109
EDTA plasma (n=4) 89 85-93
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/ml OD1 OD2 Average Corrected
10 2.524 2.631 2.578 2.404
5 1.957 1.904 1.931 1.757
2.5 1.240 1.304 1.272 1.098
1.25 0.753 0.768 0.761 0.587
0.625 0.496 0.511 0.504 0.330
0.312 0.302 0.320 0.311 0.137
0.156 0.220 0.234 0.227 0.053
0 0.176 0.172 0.174  
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx
Description

This Mouse ROBO4 ELISA Kit was designed for the quantitative measurement of Mouse ROBO4 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.156 ng/mL-10 ng/mL and the sensitivity is 0.039 ng/mL.

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

Target Background

Function
(From Uniprot)
Receptor for Slit proteins, at least for SLIT2, and seems to be involved in angiogenesis and vascular patterning. May mediate the inhibition of primary endothelial cell migration by Slit proteins. Involved in the maintenance of endothelial barrier organization and function.
Gene References into Functions
  1. Robo4 inhibits angiogenesis and vessel permeability independently of its cytoplasmic domain. Robo4 deletion enhances permeability and revascularization in oxygen-induced retinopathy (OIR) and accelerates cutaneous wound healing. PMID: 27882935
  2. endothelial Robo4 signaling is important for suppressing breast cancer growth and metastasis, and it can be targeted (enhanced) by administrating a small molecular drug. PMID: 26778715
  3. Robo4 vaccines induce antibodies that retard tumor growth. PMID: 25348086
  4. Robo4 and Src family kinases are involved in the mechanisms of embryonic vascular defects caused by the Hrt/Hey deficiency. PMID: 25264302
  5. These results clearly indicate that Robo4 plays a role in hematopoietic stem cells trafficking such as bone marrow homing and peripheral mobilization. PMID: 23226403
  6. our results showed an important role of Robo4 in the regulation of cortical radial migration through Slit-dependent and -independent mechanisms PMID: 22123939
  7. Data found that expression of Slit2 and SDF1 were dynamically regulated in mesenchymal stem cells and OBC-like populations following radiation, while Robo4 expression was restricted to endothelial cells. PMID: 22313734
  8. augmenting the host Robo4/Slit2 system could provide a useful therapeutic approach to control pathological angiogenesis associated with HSV induced stromal keratitis PMID: 21572022
  9. Robo4 specifically binds to UNC5B, a vascular Netrin receptor, revealing unexpected interactions between two endothelial guidance receptors. PMID: 21238923
  10. Activating with the soluble ligand Slit an endothelium-specific, Robo4-dependent signaling pathway that strengthens the vascular barrier, diminishing deleterious aspects of the host's response to the pathogen-induced cytokine storm. PMID: 20375003
  11. enhanced growth of blood vessels in Robo4(-/-) endothelium is due to activation of vascular endothelial growth factor (VEGF)-R2 signaling through the Src and FAK kinases. PMID: 20498081
  12. Robo4 is a bona fide member of the Robo family and may provide a repulsive cue to migrating endothelial cells during vascular development. PMID: 12941633
  13. Robo4 is expressed in hematopoietic stem cells (HSC), and Robo4/Slit2 signaling may play a role in HSC homeostasis in the bone marrow niche. PMID: 18927479
  14. Robo4 mRNA level decreases during vascular decline in pulmonary fibrosis. PMID: 17496152

Show More

Hide All

Protein Families
Immunoglobulin superfamily, ROBO family
Tissue Specificity
Expressed specifically in embryo and adult vascular endothelium.
Database Links
icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2024 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1