Human enterovirus 71 virus (EV71) antibody (IgG) ELISA kit

Code CSB-EQ027974HU
Size 96T,5×96T,10×96T
Price Request a Quote or Start an on-line Chat
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* The sample kit cost can be deducted from your subsequent orders of 96T full size kits of the same analyte at 1/5 per kit, until depleted in 6 months. Apply now

Product Details

Target Name
enterovirus 71 virus (EV71) antibody (IgG)
Abbreviation
EV71 Ab (IgG)
Species
Homo sapiens (Human)
Sample Types
serum
Detection Range
Request Information
Sensitivity
Request Information
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Others
Assay Principle
qualitative
Measurement
Indirect
Precision
Intra-assay Precision (Precision within an assay): CV%<15%      
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%<15%      
Three samples of known concentration were tested in twenty assays to assess.    
             
Typical Data
             
             
Test parameter specification test result  
Positive control >0.60 0.914  
Negative control <0.15 0.085  
Positive rate 10,Positive 100%  
Negative rate 10,Negative 100%  
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

 Q&A
Q:

I am interested in the igg Elisa kit for enterovirus 71 and would like to get more info
about the serotype of entervirus 71 that you used as antigen in the kit.
Also,could you please let me know the efficiency of the kit. Does the kit provide cross reaction with
other enteroviruses (coxsackie virus). Can I use plasma with heparin contamination with
this kit?

A:
Thanks for your inquiry!
The kit CSB-EQ027974HU is coated with a specific antigen EV71.
This kit is a qualitative kit and has no standard curve.As for the efficiency,we will send you COA soon by email..
The kit is used to detect serum. Besides, pls confirm if you typed it wrong by "plasma with heparin contamination".
If it is wrong, then it should be EDTA plasma. As for the EDTA plasma, it can be detected with this kit.
The kit has less cross activity with EV16 and coxsackie B.
icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2024 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1