Mouse Homocysteine(HCY)ELISA Kit

Code CSB-E16551m
Size 96T,5×96T,10×96T
Trial Size 24T ELISA kits trial application
Have Questions? Leave a Message or Start an on-line Chat

Product Details

Description

This Mouse Hcy ELISA Kit was designed for the quantitative measurement of Mouse Hcy protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 4.7 nmol/mL-300 nmol/mL and the sensitivity is 1.1 nmol/mL.

Target Name Homocysteine(HCY)
Alternative Names
N/A
Abbreviation Hcy
Species Mus musculus (Mouse)
Sample Types serum, plasma, tissue homogenates
Detection Range 4.7 nmol/mL-300 nmol/mL
Sensitivity 1.1 nmol/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Metabolism
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of mouse Hcy in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
 SampleSerum(n=4)
1:1Average %97
Range %92-105
1:2Average %90
Range %86-96
1:4Average %94
Range %90-98
1:8Average %99
Range %95-107
Recovery
The recovery of mouse Hcy spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample TypeAverage % RecoveryRange
Serum (n=5) 8480-88
EDTA plasma (n=4)9591-99
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
nmol/mlOD1OD2AverageCorrected
3002.437 2.352 2.395 2.222
1502.075 2.036 2.056 1.883
751.674 1.604 1.639 1.466
37.51.079 1.132 1.106 0.933
18.750.621 0.597 0.609 0.436
9.40.416 0.459 0.438 0.265
4.70.297 0.289 0.293 0.120
00.179 0.167 0.173  
ELISA Data Analysis Watch ELISA data processing video & download Curve Expert if needed
Troubleshooting
and FAQs
ELISA kit FAQs
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

 Q&A
Q:

I want to know some information regarding the kit CSB-E16551M:
The kit is labeled as 4.7-300 nmol/ml, which I assume is nmole/ml. Units are notmally expressed in nM, that is nmoles per liter (nmole/L). Could you confirm the unit is correct?

A:
Thanks for your inquiry.
This kit CSB-E16551m is specific to detect Homocysteine. Usually nM is nmol/L,but most literatures use nmol/mL(some literatures use nM, and it is due to habit) .
If you want to use nM, pls convert the unit. Pls let me know if you have any further questions. Thank you.
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
Address
7505 Fannin St Ste 610-322 Houston, TX 77054, USA
Join Us with

Subscribe newsletter

Leave a message

© 2007-2023 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1