Rabbit Endothelin 1,ET-1 ELISA Kit

Code CSB-E06951Rb
Size 96T,5×96T,10×96T
Price Request a Quote or Start an on-line Chat
Trial Size 24T ELISA Kit Trial Size (Only USD$150/ kit)
* The sample kit cost can be deducted from your subsequent orders of 96T full size kits of the same analyte at 1/5 per kit, until depleted in 6 months. Apply now

Product Details

Target Name
endothelin 1
Alternative Names
EDN1Endothelin-1 ELISA Kit; ET-1 ELISA Kit; Preproendothelin-1 ELISA Kit; PPET1) [Cleaved into: Big endothelin-1] ELISA Kit
Abbreviation
EDN1
Uniprot No.
Species
Oryctolagus cuniculus (Rabbit)
Sample Types
serum, plasma, tissue homogenates
Detection Range
6.25 pg/mL-400 pg/mL
Sensitivity
1.56 pg/mL
Assay Time
1-5h
Sample Volume
50-100ul
Detection Wavelength
450 nm
Research Area
Cancer
Assay Principle
quantitative
Measurement
Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10%
Three samples of known concentration were tested in twenty assays to assess.
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of rabbit ET-1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
 SampleSerum(n=4)
1:1Average %86
Range %80-92
1:2Average %100
Range %91-105
1:4Average %96
Range %92-104
1:8Average %94
Range %86-98
Recovery
The recovery of rabbit ET-1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample TypeAverage % RecoveryRange
Serum (n=5) 9589-99
EDTA plasma (n=4)9890-106
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/mlOD1OD2AverageCorrected
4002.630 2.456 2.543 2.458
2002.111 2.076 2.094 2.009
1001.459 1.443 1.451 1.366
500.816 0.769 0.793 0.708
250.415 0.389 0.402 0.317
12.50.218 0.203 0.211 0.126
6.250.147 0.149 0.148 0.063
00.088 0.082 0.085  
Troubleshooting
and FAQs
Storage
Store at 2-8°C. Please refer to protocol.
Lead Time
3-5 working days after you place the order, and it takes another 3-5 days for delivery via DHL or FedEx
Description

This Rabbit EDN1 ELISA Kit was designed for the quantitative measurement of Rabbit EDN1 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 6.25 pg/mL-400 pg/mL and the sensitivity is 1.56 pg/mL.

Customer Reviews and Q&A

 Customer Reviews

There are currently no reviews for this product.

Submit a Review here

Target Background

Function
(From Uniprot)
Endothelins are endothelium-derived vasoconstrictor peptides. Probable ligand for G-protein coupled receptors EDNRA and EDNRB which activates PTK2B, BCAR1, BCAR3 and, GTPases RAP1 and RHOA cascade in glomerular mesangial cells.
Gene References into Functions
  1. Study shows that cerebrovascular muscle cells can express endothelin-1 (ET-1). The production of ET-1 in cerebrovascular muscle cells stimulated by oxyhemoglobin occurs partially through the NF-[kappa]B signal pathway. PMID: 27391329
  2. Plasma ET-1 levels of rabbits increased significantly in fluorinated groups compared with those in the control group. PMID: 27941335
  3. Dynamic monitoring and comparison of plasma levels of ET, CGRP, NO, and MDA as well as SOD activity revealed that appropriate intervention of these factors may reduce reperfusion injury PMID: 26125755
  4. In a saline lavage-induced lung injury model, both circulatory and pulmonary ET-1 levels increased. PMID: 24735960
  5. Data suggest elevated levels of endothelin-1, as exhibited in cardiovascular diseases, facilitate development of ventricular arrhythmia by steepening action potential duration restitution and by increasing beat-to-beat variability of repolarization. PMID: 24084217
  6. High levels of ET-1 are closely associated with BBB disruption. ET-1 may play an important role in the pathogenesis of secondary brain injury after ICH. PMID: 24034085
  7. After subarachnoid hemorrhage, the contractile response to ET-1 was enhanced, and the ET(A) receptor expression was upregulated in the basilar artery. PMID: 21952110
  8. After acute pulmonary thromboembolism, thrombolytic and anti-inflammatory treatment could decrease acute lung injury induced by ET-1 and NF-kappaB activation. [endothelin-1; NFKB] PMID: 16207427
  9. The increase in myocardial distensibility induced by endothelin-1 is absent in heart failure and is dependent on nitric oxide and prostaglandin release. PMID: 17552879
  10. Endothelin-1 enhances nuclear Ca2+ transients in atrial myocytes through Ins(1,4,5)P3-dependent Ca2+ release from perinuclear Ca2+ stores PMID: 18089647
  11. The enhancement of gap junction intercellular communication is activated by endothelin-1 via modulating the expression of connexin43, and plays an important role in the pathogenesis of cerebral vasospasm PMID: 18691452

Show More

Hide All

Subcellular Location
Secreted.
Protein Families
Endothelin/sarafotoxin family
Database Links
icon of phone
Call us
301-363-4651 (Available 9 a.m. to 5 p.m. CST from Monday to Friday)
icon of address
Address
7505 Fannin St., Ste 610, Room 7 (CUBIO Innovation Center), Houston, TX 77054, USA
icon of social media
Join us with

Subscribe newsletter

Leave a message

* To protect against spam, please pass the CAPTCHA test below.
CAPTCHA verification
© 2007-2024 CUSABIO TECHNOLOGY LLC All rights reserved. 鄂ICP备15011166号-1