Code | CSB-EL005490HU |
Size | 96T,5×96T,10×96T |
Price | Request a Quote |
Trial Size |
24T ELISA Kit Trial Size (Only USD$150/ kit) * Sample kit cost can be deducted as a $30 credit for each 96-assay kit of the same analyte and brand you subsequently purchase within six months until depleted. More details >> Interested in a trial size? Please leave a message below.
|
Have Questions? | Leave a Message or Start an on-line Chat |
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
To assess the linearity of the assay, samples were spiked with high concentrations of human CLDN1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
Sample | Serum(n=4) | |||||
1:1 | Average % | 91 | ||||
Range % | 87-96 | |||||
1:2 | Average % | 97 | ||||
Range % | 95-100 | |||||
1:4 | Average % | 101 | ||||
Range % | 94-105 | |||||
1:8 | Average % | 93 | ||||
Range % | 90-96 |
The recovery of human CLDN1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 91 | 86-97 | ||||
EDTA plasma (n=4) | 99 | 93-102 | ||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]()
|
The human Claudin-1 (CLDN1) ELISA kit is recommended for detecting CLDN1 levels in various samples, including serum, plasma, tissue homogenates, and cell lysates. This quantitative sandwich assay has a detection range of 15.6 pg/mL to 1000 pg/mL with a sensitivity of 3.9 pg/mL, making it highly precise in measuring CLDN1 concentrations. With an assay time of 1-5 hours and a sample volume requirement of 50-100 µl, it offers efficiency and flexibility in experimental settings. The detection wavelength of 450 nm ensures accurate and reliable results. The ELISA kit's principle of operation aligns with the sandwich method, which is crucial for its quantitative capabilities. Moreover, its extensive utilization in over 8 research papers underscores its reliability and relevance in scientific investigations related to CLDN1.
There are currently no reviews for this product.