Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
To assess the linearity of the assay, samples were spiked with high concentrations of human IP-10 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
| Sample | Serum(n=4) | ||||
1:1 | Average % | 98 | ||||
Range % | 94-103 | |||||
1:2 | Average % | 89 | ||||
Range % | 85-95 | |||||
1:4 | Average % | 101 | ||||
Range % | 96-107 | |||||
1:8 | Average % | 97 | ||||
Range % | 92-103 | |||||
The recovery of human IP-10 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 92 | 86-98 | ||||
EDTA plasma (n=4) | 97 | 90-100 | ||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||
| |||||||
pg/ml | OD1 | OD2 | Average | Corrected | |||
1000 | 2.998 | 3.134 | 3.066 | 2.942 | |||
500 | 1.662 | 1.667 | 1.664 | 1.541 | |||
250 | 1.010 | 0.978 | 0.994 | 0.870 | |||
125 | 0.520 | 0.529 | 0.525 | 0.401 | |||
62.5 | 0.362 | 0.341 | 0.352 | 0.228 | |||
31.2 | 0.219 | 0.229 | 0.224 | 0.100 | |||
15.6 | 0.180 | 0.184 | 0.182 | 0.058 | |||
0 | 0.122 | 0.125 | 0.124 |
| |||
This ELISA kit provides quantitative measurement of CXCL10 (IP-10) in human samples, supporting research into interferon-γ-driven immune signaling and chemokine-mediated T cell recruitment. Because CXCL10 levels can shift dramatically between homeostatic and inflammatory states, the kit is designed to capture this dynamic range without requiring extensive sample manipulation.
Detection Range: The 15.6–1000 pg/mL range spans baseline circulating CXCL10 concentrations in healthy serum (~50–300 pg/mL) through the elevated levels seen in active viral infection, autoimmunity, or transplant rejection, often exceeding 500 pg/mL. Most serum and plasma samples can be assayed neat or with minimal dilution, while inflamed tissue homogenates may require titration.
Sensitivity: At 3.9 pg/mL, the kit detects CXCL10 in low-expression contexts such as early post-infection timepoints, immunosuppressed patient plasma, or unstimulated cell culture supernatants where concentrations fall well below normal circulating levels.
Sample Compatibility: Validation across serum, plasma, and tissue homogenates enables paired systemic-versus-local analyses — for example, correlating circulating CXCL10 with intratumoral or graft-site chemokine gradients within a single study.
Assay Efficiency: The 1–5 hour protocol and 50–100 µL sample volume accommodate longitudinal clinical cohort studies and small-volume pediatric or biopsy-derived specimens where repeated sampling is necessary.
This kit is well suited for studies of viral hepatitis immune monitoring, solid organ transplant rejection, and tumor immune microenvironment profiling.